Sign In | Join Free | My ledscreensign.com |
|
Brand Name : MEMBRAPOR
Model Number : CO/CF-200
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5000pcs/Month
Packaging Details : Standard Box
Operation Principle : 3-Electrode Electrochemical
Nominal Range : 0 - 200 ppm
Maximum Overload : 400 ppm
Inboard Filter : To remove acidic gases
Output Signal : 700 ± 200 nA/ppm
Resolution (Electronics dependent) : < 0.1 ppm
T90 Response Time : < 50 s
Typical Baseline Range (pure air, 20°C) : -1.0 ppm to 1.0 ppm
Maximum Zero Shift (+20°C to +40°C) : see Graph
Repeatability : < 2 % of signal
CO/CF-200 Carbon Monoxide Gas Sensor CO Air Quality Monitoring
Applications
• Continuous Air Quality Monitoring
• Safety and Environmental Control
Specification Sheet
Rec. Load Resistor | 10 - 33 Ω |
Bias (V_Sens-V_Ref) | not recommended |
Conformity to RoHS directive | RoHS Compliance |
Relative Humidity Range | 15 % to 90 % RH non-condensing |
Temperature Range | -40 °C to 50 °C |
Pressure Range | Atmospheric |
Pressure Coefficient | N.D |
Humidity Effect | None |
Expected Operation Life | 3 years in air |
Expected Long Term Output Drift in air | < 2 % signal loss per month |
Storage Life | 6 months in container |
Rec. Storage Temperature | 5°C - 20°C |
Warranty Period | 12 months from date of dispatch |
Cross Sensitivity Data
The table below does not claim to be complete. We recommend using the target gas
for calibration purposes. Using surrogate (interfering) gases can result in
inaccuracies in the final calibration. Please contact Membrapor AG for further support
regarding cross sensitivities.
![]() |
CF-200 Carbon Monoxide Gas Sensor 400 ppm CO Air Quality Monitoring Images |