Sign In | Join Free | My ledscreensign.com
China ShenzhenYijiajie Electronic Co., Ltd. logo
ShenzhenYijiajie Electronic Co., Ltd.
The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates
Verified Supplier

4 Years

Home > Oxygen Gas Sensor >

MOX4 AA829-M20 MOX-4 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In Ventilator Anesthesia Machine And Oxygen Concentration Monitoring And

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

MOX4 AA829-M20 MOX-4 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In Ventilator Anesthesia Machine And Oxygen Concentration Monitoring And

  • 1
  • 2
  • 3

Model Number : MOX4 AA829-M20 MOX-4

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time : 3-5work days

Operating Principle : Partial pressure electrochemical

Output : 9 mV to 13 mV in 210 mBar O2

Measurement Range : 0 mBar to 1500 mBar O2

Response Time (T90) : <15 s (air to 100% O2)

Baseline Offset : <200 μV

Linearity : Linear 0% to 100% O2

Contact Now

MOX4 Oxygen Sensor
Part Number: AA829-M20

Document Purpose:
The purpose of this document is to present the performance specification of the MOX4 oxygen gas sensor.
This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

If the Sensor is Dropped:
If a sensor is dropped, then it should be placed in quarantine for 24 hours and a follow-up check made by a 2-point calibration.

Mechanical Installation:
When installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.

RFI/EMI Susceptibility:
MediceLs contain metal and may be susceptible to RFI or EMI. They are not suitable for use in MRI environments. For further information, please contact City Technology.

Housing Material White ABS
Weight 42 g (nominal)
Orientation Any
Typical Applications Critical care anesthesia
Operating Temperature Range -20°C to +50°C

MOX4 AA829-M20 MOX-4 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In Ventilator Anesthesia Machine And Oxygen Concentration Monitoring And


Product Tags:

Widely Used Oxygen Gas Sensor

      

MOX4 Oxygen Gas Sensor

      
Quality MOX4 AA829-M20 MOX-4 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In Ventilator Anesthesia Machine And Oxygen Concentration Monitoring And for sale

MOX4 AA829-M20 MOX-4 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In Ventilator Anesthesia Machine And Oxygen Concentration Monitoring And Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)